syringe filter chemical compatibility chart

Nalgene Syringe Filter non

Nalgene Syringe Filter non-SterilePTFE membrane 0 45 um 25mm diameter Code: fil8350 C7-46 Key Features Sterility Assurance – 3 year shelf life for sterile syringe filters with lot number and expiration date printed on individual packages Nalgene sterile and non read more ADD 2 071 00 PK500 List Price REQUEST REQUEST A QUOTE OVERVIEW DOCUMENTS RANGE Open the

TECHNICAL INFORMATION OMICRON CHEMICAL COMPATIBILITY CHART

TECHNICAL INFORMATION OMICRON CHEMICAL COMPATIBILITY CHART - MEMBRANE FILTER Chart below shows the Chemical Compatibility of various types of membrane filters with some commonly used chemicals All types of membrane filter products were exposed to specified chemicals/reagents for 3 days at 250C Upshot: All products retain its Integrity after Chemical compatibility Test C = Compatibility

Syringe Filter Chemical Compatibility

Chemical compatibility is a critical consideration when selecting the proper sample prep syringe filter for your application This chart outlines the chemical compatibility of the most common syringe filters Syringe Filter Chemical Compatibility Syringe Filter Regenerated Chemical Compatibility Cellulose (RC) Polytetrafluoroethylene (PTFE

PTFE Chemical Resistance Chart

PTFE Chemical Resistance Chart PTFE extruded tubing and PTFE shrink tubing are used by our customers in various industries and in different applications which may require resistance to specific chemicals While this chart is a useful reference please note that it is the end users' responsibilities to evaluate and test the fitness of the product for their specific applications

Chemical Compatibility Plastic Material Chart for PA66

Chemical Compatibility Plastic Material Chart for PA66 PEEK PPS PVDF and POM PA66 = polyamide 66 PEEK = polyetheretherketone PPS€€ = polyphenylene sulphide PVDF = Polyvinylidene fluoride POM = polyoximethylene acetal Ratings -- Chemical Effect A = Excellent B = Good -- Minor Effect slight corrosion or discoloration C = Fair -- Moderate Effect not recommended for continuous

KYNAR PVDF Chemical Compatibility Resistance Chart

KYNAR (PVDF) Chemical Compatibility Chemical Resistance Chart Explanation of Footnotes 1 Satisfactory to 72F (22C) 2 Satisfactory to 120F (48C) Ratings -- Chemical Effect • A = Excellent • B = Good -- Minor Effect slight corrosion or discoloration • C = Fair -- Moderate Effect not recommended for continuous use Softening

Syringe Filters Solvent Compatibility Chart

Syringe Filters Compatibility Chart R = Recommended No significant change observed in flow rate or bubble point of the membrane nor visible indication of chemical attack L = Limited Recommended Use Moderate changes in physical properties The filter may be suitable for short term non-critical use N = Not Recommended The membrane may be

Masterflex Tubing Chemical Compatibility from Cole

The information in this chart has been supplied to Cole-Parmer by other reputable sources and is to be used ONLY as a guide in selecting equipment for appropriate chemical compatibility Before permanent installation test the equipment with the chemicals and under the specific conditions of your application

Filter Bags Cartridges and Vessels for Chemical and

Welcome to Filter Specialists Inc Established in 1972 FSI is the world's most innovative manufacturer of liquid filtration products We've patented dozens of designs for filter vessels filter bags and filter cartridges providing our customers with improved efficiency and significant cost savings

KP8

Syringe Filter Information A syringe filter generally consists of a plastic housing with a membrane which serves as a filter The fluid to be purified may be cleaned by pressing it through the syringe through the filter The following chart is designed to help in selecting the correct filter for your project Standard Syringe Filter Products 30mm

Membrane Filter Chemical Compatibility Chart

Syringe Filter Housings 1) Syringe filter housings are manufactured from solvent-resistant low-extractable polypropylene resins specifically selected for wide compatibility with common HPLC sample matrices 2) Solutions at temperatures up to 100C can be filtered using syringe filters 3) Syringe filters can be sterilized by autoclave at 125

Laboratory Filters : Waters

Filter Design Pall Life Sciences broad range of device sizes assures complete sample filtration with minimal sample loss In addition many Acrodisc syringe filters offer the option of a minispike outlet rather than the traditional male luer outlet The minispike outlet available on 13 mm PTFE Nylon GH Polypro and PVDF Acrodisc syringe filters allows for easy dispensing into

Syringe filters: Scharlab: Scharlab S L The Lab

The result is a high-quality syringe filter fulfilling the needs of the most demanding chromatographers Nylon: nylon syringe filters have become the standard material due to their wide chemical compatibility and their hydrophobic nature They can be used for filtering aqueous samples and most solvents Nylon Premium filters are subjected to a double quality control for the most demanding

Rubber Chemical Resistance Chart Rubber Compatibility

Use this rubber chemical resistance chart to make sure that the elastomer or O-ring seal you choose will be compatible with the particular environment The chemical compatibility of rubber is extremely important as the rubber can degrade rapidly if the rubber material is not compatible with the environment or media that it comes into contact with LEGEND: 1 = Satisfactory 2 = Fair 3

6 ways to know the syringe filter better

The syringe filter body may be made of such materials as polypropylene and nylon The filter membrane may be of PTFE nylon or other treated products for specific purposes Most manufacturers publish compatibility wall charts advising users of compatibility between their products and organic solvents or corrosive liquids (e g trifluoroacetic acid) I have attached the National Scientific

Polyethylene Terephthalate (PET)

Polyethylene Terephthalate (PET)--Chemical Compatibility G = PET exhibits good resistance to attack F = PET exhibits fair resistance to attack X = PET exhibits poor resistance and should not be considered for this application Substance Physical state or concentration Suitability The data provided below should not be construed as implying a legal guarantee

Frequently Asked Questions: Sample Preparation /

Frequently Asked Questions: Sample Preparation Frequently Asked Questions: Sample Preparation and the Syringe Filter Solvent Compatibility Chart Best practices dictate verifying compatibility prior to use Syringe Filter Membrane Selection Guide Membrane Properties Applications Incompatible with Cellulose Acetate hydrophilic aqueous solutions organic solvents

In

In-line and syringe filter holders are available in various materials and sizes Use PFA in-line holders with chemically-aggressive liquids Select polycarbonate filter holders for aqueous solutions Polypropylene (PP) holders are ideal for ultra-cleaning and sterilizing liquids under pressure or for aseptic sampling of liquids and gases We have a filter holder to meet your needs

Minisart Syringe Filter Units

Minisart syringe filters are ready-to-use filter units offering high flow rates at low inlet pressures to make rapid filtration of possible Fitted onto a syringe they enable a less hand-tiring sterilization of up to 100 ml of liquid A Minisart fitted on a standard dosing syringe makes up a very convenient system for simultaneous dosing and sterilization For larger volumes either Sartolab

Solvent Compatibility Chart for Syringe Filters

Syringe Filters Compatibility Chart R = Recommended No significant change observed in flow rate or bubble point of the membrane nor visible indication of chemical attack L = Limited Recommended Use Moderate changes in physical properties The filter may be suitable for short term non-critical use N = Not Recommended The membrane may be

Phenomenex Filtration Part: Phenex™

Phenex Syringe Filter Chemical Compatibility Chart: Add to My Documents: Brochures UHPLC Column and System Protection Essentials/ Accessories: Add to My Documents: Technical Notes Ibuprofen Tablet USP Dissolution: A Rapid HPLC Alternative to the Traditional UV Method (TN-1248) Add to My Documents: Technical Notes

Chemical Compatibility Chart for Reusable Gloves from

Chemical Compatibility Chart For Reusable Gloves A Warning: The information in this chart was supplied to by other reputable sources and is to be used ONLY as a guide in selecting gloves for chemical compatibility testing Variability in material thickness chemical concentration temperature and length of exposure to chemicals will affect specific performance

Chemical Resistance Recommendations

Chemical Resistance Recommendations Chemical Name Formula SP Grav Polypropylene Polyester Polyamide Aramid (Nomex) Wool Cotton Viscose/Phenolic NBR EPDM PTFE Silicone FPM (Viton) SS-316 SS-304 CST Hastelloy C4 SAN PVC CPVC E-CTFE (HALAR) PVDF Acetaldehyde CH3CHO 50 60 A A X C 175 C X A A C A X X B Acetaldehyde Aqueous 50 60 C X 175 X A A C X X A Acetamide

Syringe filter compatibility chart Keyword Found

Membrane Filter Chemical Compatibility Chart - Support Scientificfilters Syringe Filter Housings 1) Syringe filter housings are manufactured from solvent-resistant low-extractable polypropylene resins specifically selected for wide compatibility with common HPLC sample matrices 2) Solutions at temperatures up to 100C can be filtered

Online customer service

Welcome ! If you have any questions or suggestions about our products and services,please feel free to tell us anytime!